    USA SHIP!  SPO2 Pulse rate Patient Simulator, Oxygen saturation Simulator  MS100
    Brief Introduction
    MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
    Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
    Features
    ◆ Separated connection between simulator probe and host, operation and test are more convenient.
    ◆ 262K color and 320*240 TFT, adjustable brightness level.
    ◆ Film key-press, makes the operation more comfortable.
    ◆ Power with chargeable lithium battery, can display the charge information of battery.
    ◆ Key volume, can open or close.
    Main Functions
    ◆ Oxygen saturation simulation;
    ◆ Pulse rate simulation;
    ◆ Patient state simulation preset;
    ◆ Can test the reaction time of device;
    ◆ Can simulate the SpO2 and pulse rate under different amplitude;
    ◆ Can test the performance of device under different interference source;
    ◆ Can select different R-curve.
    Main Parameters
    ◆ SpO2
    Measuring range: 35%~100%
    Resolution:1%
    Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
    ◆ Pulse rate
    Measuring range:25bpm~250bpm
    Resolution:5bpm
    Error:1%±1bpm
    ◆ Amplitude
    Measuring range:0.000%~20.000%
    Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
    ◆ Patient state
    24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
    ◆ Voltage
    DC 3.6V~4.2V
    ◆ Power Supply
    Voltage 3.7 rechargeable lithium battery × 1
    ◆ Battery working life
    Charge and discharge no less than 500 times.
    Accessaries
    ◆ A  MS100 user manual
    ◆ A  5.0V adaptor