-40%
RIGEL 322 // Pulse Oximetry Analyzer
$ 522.72
- Description
- Size Guide
Description
The unit is in excellent cosmetic condition,comes with a soft carrying case and a two pairs of connection cables, and user manual. Each cable set has a cable to connect SPO2 main unit and sensor.
The unit has been tested for proper operation and the results were successfully compared to a calibrated unit. Measurements available upon request with an extra cost.
Bio-Tech.gr is a specialized company that offers quality biomedical testing equipment and medical equipment in general.
We can have the unit calibrated to a specialized laboratory on request. Please inform us in advance and we will
quote you the related cost. The unit is not calibrated but it is thoroughly tested for good operation.
////////////////
Other Pulse Oximetry Testers only do half the job. The Rigel 322 Pulse Oximetry Analyzer is the tester that does the complete job by providing the industry's first Probe Analyzer. The Probe Analyzer includes a Probe Continuity Test that tests the probe independently and can thus isolate opens and shorts - even intermittent ones like those shown in the screen below. Since most pulse oximetry failures are ultimately traced to the probe, Rigel 322’s Probe Analyzer can save you hours of troubleshooting time.
Make sure your pulse Oximetry Tester can do the complete job:
• Probe Continuity test
• Direct Electrical Simulation
• Automatic Data-Logging
• Stored Printing
• Otis¨/medTester Compatible
When you need an SpO2 simulator, why fool around with testers that use the optical "finger" simulation method? Most pulse oximeter manufacturers do not endorse optical finger simulation because it can actually introduce uncertainty into the SpO2 simulation test. Rigel 322 is the universal SpO2 simulator which uses the manufacturer-approved "direct electrical simulation" method to provide unmatched accuracy and reliability. In fact, Rigel 322is used by leading pulse oximeter manufacturers and is emerging as the industry standard pulse oximetry tester.
Rigel 322 also allows you to document your test results efficiently. Automatic Data-Logging provides closed loop testing via a serial cable between Rigel 322 and the pulse oximeter. After testing, you can either print the results immediately or use Stored Printing to save the results for printing or uploading at a later time.
Rigel 322 can even up-load test results into popular equipment management programs such as Otis¨/Profile¨ and medTester/Sentinel.
Rigel 322
Pulse Oximetry Analyzer
Technical Specifications:
SpO2 Simulator
Oxygen Saturation (SpO2)
Range:
0-100 SpO2%
Resolution:
1 SpO2%
Accuracy:
±0.5 SpO2%, 70-100 SpO2% ±1 SpO2%, 50-69 SpO2%
Pulse Rate
Range:
20-255 bpm
Resolution:
1 bpm
Accuracy:
±1 bpm, 20-199 bpm // ±2 bpm, 200-255 bpm
R-Curves (Red/IR Ratio)
R-Curves specify the relationship between the Red/IR ratio measured by pulse oximeters and the SpO2 value displayed. R-curves are obtained by each pulse oximeter manufacturer during clinical trials.
Preset Manufacturer's R-Curves (13):
BCI, Criticare, CSI-Spot, Datascope, Datex, Hewlett-Packard, Masimo, Nellcor, Nihon Kohden, Nonin, Novametrix, Ohmeda & Sensormedics
Plethysmographic Amplitude
Simulates the effect of tissue perfusion
Range:
0-200% of nominal amplitude
Resolution:
1%
Accuracy:
±1
Ambient Light
Simulates the ambient light level "seen" by the oximeter probe
Range:
DC Level & AC
Level:
0-255%
Resolution:
1%
Accuracy:
±1%
Flicker Frequency Presets (6):
60 Hz 120 Hz 121 Hz 50 Hz 100 Hz 101 Hz
Motion Artifact
Amplitude Range:
0-100
Frequency:
4 Hz, Contact factory for availability of other frequencies.
Arrhythmias
Simulates cardiac arrhythmias by altering the plethysmographic pulse amplitude and pulse rate.
Arrhythmias (5):
Asystolic Pause PVC Atrial Fibrillation Tachycardia Bradycardia
Auto Sequences
Preset Auto Sequences automate pulse oximeter testing.
Standard Presets (5):
CalDown - decreasing SpO2 and increasing Pulse Rate at 20 second intervals
CalUp - increasing SpO2 and decreasing Pulse Rate at 20 second intervals CalLong - decreasing SpO2 and increasing Pulse Rate at 30 second intervals
FullSwp - tests every SpO2 point between 60 and 100 at 21 second intervals Trend - Sleep Apnea pattern over 60 minutes.
Automatic Data-Logging & Printing
Closed-loop testing of pulse oximeters can be achieved by connecting a cable between the "SERIAL COMM" port of the oximeter and the "RS-232" port of the Rigel 322. Oximeter test results are automatically retrieved and displayed on the Rigel 322screen; the test results can be printed immediately or stored for future printing.
Serial data protocols supported:
BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor, Nihon Kohden, Nonin, Novametrix & Ohmeda Please contact the factory for the availability of other serial data protocols.
Stored Printing
Stored Printing allows the user to save test results for printing at a later time or up-loading into popular equipment management programs such as Otis¨/Profile¨ and medTester/Sentinel.
Remote Control
The Rigel 322 can be operated via remote control through its RS-232 port. In addition to duplicating all front panel operations, remote control commands include status query commands, a keypad lock command and a "warm-boot" command.
Probe Analyzer
Probe Continuity Test
Simultaneous Channels:
2 for Nellcor-style probes: LED & PhotoDiode circuits
3 for Ohmeda-style probes: Red LED, IR LED & PhotoDiode circuits
Test Mode:
Constant Current Stimulus, Voltage Output
Constant Current Stimulus:
500 uA
Intermittent "Glitch" Detection:
Detects open circuits and short circuits, 1 msec or longer
Probe Connection:
Connectors for Nellcor & Ohmeda probes are built into Rigel 322; other probes are connected via adapter cables
General
Display
Type:
Backlit graphic LCD
Resolution:
320 h x 240 v, 0.30mm dot pitch
Controls:
Contrast, Backlight Timeout
Serial Interface
Type:
RS-232C, 9 pin "PC-AT" style
Baud Rates:
300-9600 bps
Modes:
Remote Control, Data-Logging & Equipment Management Up-Loading
Printer Interface
Type:
Centronics, 25 pin "IBM-PC" style
Battery & AC Adapter
Battery
Type:
19.2V, Nickel Metal Hydride (NimH)
Capacity:
2.1A-Hr (About 4.5 Hours usage)
Charge Time:
17 Hours (charges even if Rigel 322in use)
External AC Adapter
Type:
Wallmount Linear
Input:
120VAC, 60Hz or 230VAC, 50Hz
Output:
24VDC, 500mA
Safety Agency Approvals:
UL, CSA, TUV
Physical
Case:
Aluminum with non-skid feet & handle
Dimensions:
203 x 203 x 127 (WxDxH in mm)
Weight:
<2 Kg including battery
Rigel 322 Cables
A set
of 2
included in purchase price (please see description of specific device)
Additional sets available at extra charge
SpO2 Simulator Adapter Cables:
BCI, Criticare, CSI-Spot, Datascope, Datex, HewlettPackard, Masimo, Nellcor, Nihon Kohden, Nonin, Novametrix,Ohmeda & Sensormedics
Probe Analyzer Adapter Cables:
Criticare, Datascope, Datex, Hewlett-Packard, Masimo, Nihon Kohden, Novametrix & Sensormedics Note: BCI, Nellcor, Nonin & Ohmeda probes connect directly.
Optional Accessories
Automatic Data-Logging Cables:
BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor, Nihon Kohden, Nonin, Novametrix & Ohmeda
Otis/medTester Interface:
Rigel 322 can up-load test results into Otis¨/Profile¨ and medTester/Sentinel equipment management systems.
Rigel 322
Carry Case