-40%

Fedex CONTEC ECG NIBP SPO2 Patient Simulator Blood Oxygen Testor+warranty, USA

$ 210.67

Availability: 15 in stock
  • Brand: CONTEC
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • MPN: 69450401
  • Country/Region of Manufacture: United States
  • Item must be returned within: 60 Days
  • Condition: New
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back

    Description

    MS100 MS200 MS400 simulator
    Description
    Brief Introduction
    MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
    Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
    Features
    ◆ Separated connection between simulator probe and host, operation and test are more convenient.
    ◆ 262K color and 320*240 TFT, adjustable brightness level.
    ◆ Film key-press, makes the operation more comfortable.
    ◆ Power with chargeable lithium battery, can display the charge information of battery.
    ◆ Key volume, can open or close.
    Main Functions
    ◆ Oxygen saturation simulation;
    ◆ Pulse rate simulation;
    ◆ Patient state simulation preset;
    ◆ Can test the reaction time of device;
    ◆ Can simulate the SpO2 and pulse rate under different amplitude;
    ◆ Can test the performance of device under different interference source;
    ◆ Can select different R-curve.
    Main Parameters
    ◆ SpO2
    Measuring range: 35%~100%
    Resolution:1%
    Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
    ◆ Pulse rate
    Measuring range:25bpm~250bpm
    Resolution:5bpm
    Error:1%±1bpm
    ◆ Amplitude
    Measuring range:0.000%~20.000%
    Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
    ◆ Patient state
    24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
    ◆ Voltage
    DC 3.6V~4.2V
    ◆ Power Supply
    Voltage 3.7 rechargeable lithium battery × 1
    ◆ Battery working life
    Charge and discharge no less than 500 times.
    Accessaries
    ◆ A  MS100 user manual
    ◆ A  5.0V adaptor
    Product overview
    MS200 NIBP Simulator is a multi-purpose tester applied to the oscillometric Non-Invasive Blood Pressure (NIBP)Monitor. It can test the performance of multiform blood pressure monitor, provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.
    Main features
    ◆ 4.3" LCD display,interface is concision,operation is simple and convenient.
    ◆ Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
    ◆ Build-in pump provides pressure source with leak and pressure relief tests
    ◆ NIBP simulations for both arm and wrist cuffs.
    ◆ Provides adult,neonate, seven variations patients conditions,user-defined simulations.
    ◆ Provides arrhythmias,respiratory artifact simulations.
    ◆ Built-in air chamber to simulate adult and neonate cuff.
    Main Parameters
    ◆ Heart Rate for NIBP Simulations
    Heart Rate Accuracy:   ±1BPM
    Patient Conditions:
    Weak pulse,Tachycardia,Obese ,Geriatric: ±1% ±1BPM
    Mild exercise:     ±1.5% ±1BPM
    Strenuous exercise:    ±3% ±1BPM
    ◆ Pressure measurement
    Units:      mmHg,kPa,cmH2O,inH2O,psi
    Range:      0 mmHg-400 mmHg
    Resolution: 1 mmHg,  0.1 kPa, 1 cmH2O,  1 inH2O,  0.1 psi
    Accuracy:   0 - 300 mmHg: ±0.5 % of reading ±1 mmHg           301 - 400 mmHg: ±2 % of reading
    ◆ Pressure Generation
    Pressure Generator, Static Pressure Range: 50 mmHg-400 mmHg
    Difference between target pressure and actual pressure : ±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
    Internal leak rate: <2 mmHg per minute, with a minimum volume of 300 cc
    ◆ Power
    100 - 240 V  AC 50/60 Hz, 60 VA
    ◆ Environmental Conditions
    Working temperature:  15℃ to 40℃(59℉ to 104℉)
    Storage temperature:  -20℃ to +65℃(-4℉ to +149℉)
    Relative humidity:    < 90%
    ◆ Display
    65k colors 4.3 inch TFT Display, brightness can be changed.
    ◆ Size (L x W x H)
    27 cm x 26.5 cm x 13.2 cm
    ◆ Weight
    3.5kg
    Accessories:
    Power cord
    Fuse
    User 's Manual
    Introduction
    MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement. It can check the monitor rapidly near the bed, also can test the quality warranty of ECG equipment, monitor and remote therapy equipment, At the same time, it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
    ■3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
    ■Display the output waveforms synchronously, which is convenient for user to
    compare with the   test equipment.
    ■It integrates the functions of SD socket interface, user can output the
    custom waveform by this   device.
    ■Built-in templates list to provide the waveform that is expressed by each
    preset sequence   number,which is convenient for searching.
    ■Two operation interfaces:Chinese and English.
    ■Operate with keystroke and touch-screen expediently and rapidly.
    ■Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
    ■Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
    ECG/Arrhythmia
    ECG
    ■Conventional: All leads have the same voltage with the II-lead as the reference
    ■Amplitude: 0.5,1.0,1.5 and 2.0mV
    ■The accuracy of Amplitude: ±2%
    ■ECG Rate:
    15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340      and 350 BPM
    ■ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
    ■The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
    ■The default: 80 BPM,1mV
    Arrhythmia
    ■Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia,
    Missed Beat, Atrial
    ■Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
    ■Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular
    Contraction (PVC) 6/min,
    ■PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired
    PVCs, Run 5
    ■PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    ■Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left
    Ventricular Focus
    ■PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early
    Right
    ■Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right
    Ventricular Focus, Multifocal PVC
    ■Conduction Defects: First Degree Heart Block, Second Degree Heart Block,
    Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch
    Block
    ECG Performance Testing
    ■ECG amplitude:0.5,1.0,1.5 and 2.0mV
    ■The accuracy of Amplitude: ±2%
    ■Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
    ■Square: 0.125 and 2.0 Hz
    ■Triangle: 2.0 and 2.5 Hz
    ■Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
    ■ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240,
    260, 280, 300,   320, 340 and 350 BPM
    ■The accuracy of ECG Rate: ±1%
    optional function:
    Respiration
    ■Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN
    ■Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    ■Baseline Impedance:500,1000,1500 and 2000
    ■Apnea: 12 s, 22 s, 32 s
    ■ECG simulator with adjustable heart rate/12-lead output
    ■33 kinds of Arrhythmia waveforms
    ■Pacemaker
    ■Two IBP channels
    ■Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32
    seconds.
    ■Standard ECG calibration
    ■Export square,triangle and sine with adjustable frequency
    IBP
    ■The default: 00/00mmHg
    ■Dynamic IBP
    Channel 1: Artery  120/80mmHg
    Radial 120/80mmHg
    Left Ventricle 120/00mmHg
    Right Ventricle 25/00mmHg
    Channel 2: Artery  120/80mmHg
    Radial 120/80mmHg
    Left Ventricle 120/00mmHg
    Right Atrium 15/10mmHg
    Right Ventricle 25/00mmHg
    Pulmonary Artery 25/10mmHg
    Left Atrium 14/4mmHg
    Static-Pressure Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100, 150, 200 and 250mmHg
    Buy Safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.  If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
    The item is registered on the Australian Register of Therapeutic Goods(ARTG) with the code 197923,
    and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved.
    Payment
    We accept payment by PayPal. PayPal enables you to make payment quickly and securely online.
    1: We accept payment via PayPal.
    2: Please pay the money within 5 days after the auction ended.
    3: Please offer home or mobile phone when the item's Value exceeds 100 (USD, EUR, AUD, GBP) so that we can
    make sure you get the item safely.
    Shipping
    1. Items are dispatched from China with in 48 hours after payment receiced or eCheck cleared.
    2.Please make sure the address and tel number are right,both of the information  is very important for delivery,thank you for your kindly cooperation.
    3.After the shipment,we will add the tracking number on both ebay and paypal  website,you can check it and track it by the number.
    4. Usually we ship this item from China by air small package,it takes about 10-45 days arrive,and we will supply a tracking number to check its state online.
    Terms of Sale
    We offer 60 days return policy. 100% satisfaction is our goal!
    1. All items are brand new, with 2 years warranty.
    2.Client is reaponsible for the custom cleatance and custom duty.
    If any, we will not be responisble for the customs clearance and duty, if you have special requirments for the declaration for your customs office, please contact us before your payment.
    3. Customer is responsible for the returning shipping fee and we will send the replacement after receiving the returned item.
    4.  Your positive feedback will be appreciated very much,  and in any case, please do contact us before leaving nagative feedback or ship the item
    back, we promise we will give you a satisfied answer.
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992
    as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.
    Most of the domestic hospitals are our customers.
    Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
    Contact Us
    Contec Medical Systems---jane