-40%

CONTEC NIBP Simulator Non-Invasive Blood Pressure simulation Simulator New MS200

$ 342.67

Availability: 100 in stock

Description

CE CONTEC MS200 NIBP SIMULATOR DYNAMIC BLOOD PRESSURE SIMULATOR,LCD DISPLAY
Product overview
MS200 NIBP Simulator is a multi-purpose  test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP)  Monitors. The appearance is concision ,operation is simple and convenient,with  its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3  kPa).The Simulator provides dynamic blood pressure simulations, static pressure  calibration, automated leak testing, and pressure relief valve testing.You can  quickly and exact analyse different NIBP Monitors.
Main features
Provides pressure gauge testing,pressure leak  testing,relief valve testing functions .
Build-in pump provides pressure source with  leak and pressure relief tests
NIBP simulations for both arm and wrist  cuffs.
Provides adult,neonate, eight variations  patients conditions,user-defined simulations.
Provides arrhythmias,respiratory artifact  simulations.
Built-in air chamber to simulate adult and  neonate cuff.
65k colors,4.3" LCD  display.
Technical index
Pressure measurement
Units:mmHg,kPa,cmH2O,inH2O,psi
Range:0mmHg-400mmHg
Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1  psi
Accuracy:0-300 mmHg:±0.5% of reading  ±1 mmHg;
301-400 mmHg:±2%of  reading
Pressure Generator
Static Pressure Range:50 mmHg-400 mmHg
Resolution:1mmHg
Difference between target pressure and actual pressure  :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
Internal leak rate
<2 mmHg per minute, with a minimum volume of 300  cc
Pressure Leak Test
Pressure generate up to 400 mmHg (53.3 kPa) with  internal pump.The screen always show the peak pressures and the real-time  pressures.Leak rate displayed after 10 seconds.
Pressure Relief Test
Pressure generate up to 400 mmHg (53.3 kPa) with  internal pump,Displays peak pressure.
Standard BP Simulations
Preset blood pressure:
1#: BP: 120/80(93) HR: 80 Pulse Volume:  0.68
2#: BP: 150/100(116) HR: 80 Pulse  Volume: 0.65
3#: BP: 200/150(166) HR:  80 Pulse Volume: 0.60
4#: BP:  255/195(215) HR: 80 Pulse Volume: 0.55
5#: BP: 60/30(40) HR: 80 Pulse Volume:  0.75
6#: BP: 80/50(60) HR: 80 Pulse  Volume: 0.71
7#: BP: 100/65(76) HR: 80  Pulse Volume: 0.69
Patient Conditions
BP Simulations
Healthy: BP: 120/80(93) HR:75 Pulse Volume:  0.68
Weak Pulse: BP: 110/80(90) HR:95  Pulse Volume: 0.50
Mild Exercise: BP:  140/90(106) HR:120 Pulse Volume: 1.00
Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume:  1.40
Obese: BP: 120/80(93) HR:90 Pulse  Volume: 0.50
Geriatric: BP:  150/110(123) HR:95 Pulse Volume: 0.40
Tachycardia: BP: 120/105(110) HR:130 Pulse Volume:  0.40
Bradycardia: BP: 120/60(80) HR:45  Pulse Volume: 1.10
Arrhythmia Simulations
Premature Atrial Contract 1,Premature Atrial Contract  2,Premature Ventricular Contract,Atrial Fib and PVCs
Respiratory Artifacts
Spontaneous Breathing 1,Spontaneous Breathing  2,Spontaneous Breathing 3,Controlled Ventilation
Neonate simulations
User can select External or Internal  Neonate;
1#: BP: 35/15 HR: 120bpm  Pulse Volume: 0.11
2#: BP: 60/30 HR:  120bpm Pulse Volume: 0.10
3#: BP:  80/50 HR: 120bpm Pulse Volume: 0.10
4#: BP: 100/70 HR: 120bpm Pulse Volume:  0.10
Wrist simulations
1#: BP:120/80(93) HR: 80bpm Pulse Volume:  0.50
2#: BP:160/100(120) HR: 80bpm Pulse  Volume: 0.50
3#: BP:80/55(63) HR: 80bpm  Pulse Volume: 0.50
User-Defined simulations
Allows the operator to define blood pressure  simulations.
Systolic(mmHg)  20-250
Diastolic(mmHg)  10-200
Heart Rate,(bpm)  30-250
Pulse Volume,(cc)  0.1-2.4
Simulant characteristics
The maximum pulse volume:2.4cc
The maximum heart rate:250bpm,200bpm at pulse  volume>2.00cc.
Internal Adult cuff  volume:20cc
Internal neonate cuff  volume:300cc
Blood pressure units:  mmHg,kPa
Heart Rate  Accuracy:±1BPM
Patient  Conditions:
Weak pulse,  Tachycardia,Obese,Geriatric ±1%±1BPM
Mild exercise±1.5%±1BPM
Strenuous exercise±3%±1BPM
Display
65k colors 4.3 inch TFT Display, brightness can be  changed.
Power
AC100 - 240 V 50/60 Hz, 60 VA
Environmental Conditions
Working temperature: 15℃ to 40℃(59℉ to 104℉)
Storage temperature: -20℃ to  +65℃(-4℉ to +149℉)
Relative humidity:  < 90%,No condensation.
Size (L x W x H)
27 cm x 26.5 cm x 13.2 cm
Weight
About 4kg
Accessories:
Power cord
Fuse
User 's Manual
Buy safe products
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved
International Buyer--Please note:
Import duties,Taxes are not included in the item price.These charges are buyers' responsibility
We are the manufacturer of medical equipment for 17 years, the following are our main products:
ECG /  ECG holter   EEG / EEG Holter      B-ultrasound
Patient Monitor      Fetal doppler             Fetal Monitor
Spo2 Monitor          Stethoscope              Medical Image...
.
Agent in the world!
We are look for partners in the world now!
Do you want  to become our agent in you conutry?
Join US!
Skype:xuebox3
contec.med.mary at hotmail.com