    CONTEC NIBP Simulator Digital Blood pressure Monitor Accuracy Simulation CE&FDA
    Introduction
    It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor.
    Functions
    Ø
    1)Pressure leak test
    Ø
    2)Over-pressure relief test
    Ø
    3)BP simulation under standard condition
    Ø
    4)BP simulation under patient condition
    Ø
    5)BP simulation under arrhythmia condition
    Ø
    6)BP simulation under respiratory interference condition
    Ø
    7)BP simulation of neonate
    Ø
    8)Wrist BP simulation
    Ø
    9)User-defined BP simulation
    Ø
    10)System setting function.
    Ø
    11)The parameters set can be stored.
    Ø
    12)ON/OFF function
    Ø
    13)Dynamic BP simulation
    Performance
    v
    BP simulation range:
    Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg)
    Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg)
    Pulse volume: 0.1 cc ~ 2.4 cc
    HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm
    HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)
    v
    Under patient condition:
    Weak pulse, tachycardia, obese, geriatric:   ±

    preset value 1%+1

    bpm
    Moderate exercise:  ±

    preset value 1.5%+1

    bpm
    Strenuous exercise: ±

    preset value 3%+1

    bpm
    v
    Pressure measurement:
    Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg)
    Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi
    v
    Accuracy:
    0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg
    40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading
    v
    Pressure leak test
    Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds.
    Over-pressure relief test
    Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure.
    v
    Pressure source:
    Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg)
    Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi
    Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc
    v
    Airtightness
    Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state
    Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min)
    BP simulation preset value configuration table
    v
    BP simulation BP preset value BP HR Pulse volume
    Standard BP simulation
    #1 120/80

    93

    80bpm 0.68cc
    #2 150/100

    116

    0.65cc
    #3 200/150

    166

    0.60cc
    #4 255/195

    215

    0.55cc
    #5 60/30(40) 0.75cc
    #6 80/50

    60

    0.71cc
    #7 100/65

    76

    0.69cc
    v
    BP simulation under patient condition
    Healthy heart 120/80(93) 75bpm 0.68cc
    Weak Pulse 110/80(90) 95bpm 0.50cc
    Mild Exercise 140/90(106) 120bpm 1.00cc
    Strenuous Exer 140/90(106) 162bpm 1.40cc
    Obese 120/80(93) 90bpm 0.50cc
    Geriatric 150/110(123) 95bpm 0.40cc
    Tachycardia 120/105(110) 130bpm 0.40cc
    Bradycardia 120/60(80) 45bpm 1.10cc
    BP simulation under arrhythmia condition
    Premature Atrial Contraction1 138/53(81) 80bpm 0.70cc
    Premature Atrial Contraction2 144/64(90) 83bpm
    Premature Ventricular Contraction 118/61(80) 83bpm
    Atrial Fibrillation and PVC 139/72(94) 91bpm
    v
    BP simulation under respiratory interference condition
    spontaneous breathing1 138/65(89) 104bpm 0.60cc
    spontaneous breathing2 149/65(93) 105bpm
    spontaneous breathing3 112/47(68) 86bpm
    controlled breathing 132/44(73) 98bpm
    v
    BP simulation of neonate
    #1 35/15(22) 120bpm 0.11cc
    #2 60/30(40) 0.10cc
    #3 80/50(60)
    #4 100/70(80)
    v
    BP simulation of wrist cuff
    #1 120/80(93) 80bpm 0.50cc
    #2 160/100(120)
    #3 80/55(63)
    v
    User-defined BP simulation[1] - - - -
    Note[1]

    Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume ≤ 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm).
    Accessories
    ü
    One User Manual
    ü
    Two fuses
    ü
    One power cord
    Physical characteristic
    ²
    Display: 4.3" 65 K color LCD display
    ²
    Power supply: AC100 ~ 240 V   50/60 Hz, <60 VA
    ²
    Environment temperature: + 5 ℃ ~ + 40 ℃
    ²
    Relative humidity: < 90 %, non-condensing
    ²
    Altitude: ≤ 3000 m
    ²
    Atmospheric pressure: 80 kPa ~ 106 kPa
    ²
    Dimension: 207 (L) × 220 (W) × 121 (H) mm
    ²
    Weight: about 2.1 kg
    Certification
    CE
    Buy Safe Product!
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and  Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an  authorized purchaser of this item before shipping of the item.
    Shipment
    1. We will ship the item within 48 hours after receiving your payment,  please kindly leave your detail shipping address and telephone number, both are very important for the shipment,thank you.
    2.We will upload the tracking number after shipment,you can search from both ebay and paypal.You can track online.
    3. If you haven't received the item after 2 weeks of your payment, please contact me immediately!
    Terms of Sale
    1.If you have a defective item, you want to return or discount. Please  contact us within 60 days from you receive the shipment.All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
    2.we will refund the money to you when we get the return items. Or replace  item for you. We will deal with the refund in 2 business days when we  get the info from you.Please read our trade Policy before buy , if you don't agree our trade policy please don't buy it.
    Only English user guide,if you need any other language,please contact us!
    Powered by SoldEazy
    Track Page Views With
    Auctiva's FREE Counter