    MS400 Touch Screen Multi Parameter Patient Simulator
    Description
    Introduction
    MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature , 2-channel IBP or 4-channel IBP, the default is 4-channel IBP. And it can be tested in where the monitor is used.
    Main Features
    ECG:
    Conventional: All leads have the same voltage with the II-lead as the reference
    Amplitude: 0.5, 1.0, 1.5 and 2.0mV
    ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
    ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
    The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
    Arrhythmia:
    ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
    Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
    Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
    Four IBP Channels:
    The default: 00/00mmHg
    Dynamic IBP(unit: mmHg)
    Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
    Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge  10/2, Left Atrium 14/4
    Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
    Channel 4:
    Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
    Man Swan-Ganz: press ENTER key to change every time
    Static-Pressure Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100, 150, 200 and 250mmHg
    Channel 3: 0, 20, 40, 60, 80 and 100mmHg
    Channel 4: P4 tracks the static pressure levels of P3
    Respiration:
    Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
    Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    Baseline impedance: 500, 1000, 1500, 2000Ω
    Apnea: 12 s, 22 s, 32 s
    Temperature:
    Four temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
    Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
    Simulate the pacemaker signal.
    Simulate the signal of standard ECG calibration.
    Including the ECG waveforms of ANSI/AAMI EC13.
    Payment
    We accept Paypal Payment.
    Shipping
    Clearance: we will ship your item to your Ebay confirmed address.
    Buyers' responsibility to pay duties,taxes and other extra charges by the government in your country.
    All items will be shipped within 2 business days by E-package,Airmail shipping.
    According to shipping method,items will be delivered within 7-35 days.
    We will do low value in PI,so that you can get items from your customs smoothly.
    Terms of Sale
    Buy safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
    If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse Oximeter that is FDA 510K Approved
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
    Contact Us
    Please contact us through
    Ebay message
    , we will reply you on line at 24 hours.
    We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely